THP Series

Up to 50 Bar: THP Series Refrigeration Dryers

KAESER offers an impressive range of compressed air refrigeration dryers for flow rates up to 106 m³/min and pressures up to 50 bar. Designed and constructed to the very highest quality standards, KAESER THP Series dryers deliver outstanding reliability and can be seamlessly integrated as part of an efficient KAESER compressed air system solution.

  • Manufacturer:

    …up to 45 Bar***
    THP 85-45

    • Flow rate at max. operational pressure** m3/min – 8.50
    • Differential pressure** bar – 0.26
    • Effective power consumption** kW – 1.01
    • Refrigerant – R 134a
    • Power Supply – 400 V, 3PH, 50Hz
    • Air connection (inner thread) – DN 25
    • Condensate Outlet – R 1/2
    • Dimensions H x W x D mm – 1277 x 1036 x 1128
    • Weight kg – 168

    THP 142-45

    • Flow rate at max. operational pressure** m3/min – 14.17
    • Differential pressure** bar – 0.40
    • Effective power consumption** kW – 1.46
    • Refrigerant – R 134a
    • Power Supply – 400 V, 3PH, 50Hz
    • Air connection (inner thread) – DN 25
    • Condensate Outlet – R 1/2
    • Dimensions H x W x D mm – 1277 x 1036 x 1128
    • Weight kg – 172

    THP 212-45

    • Flow rate at max. operational pressure** m3/min – 21.23
    • Differential pressure** bar – 0.50
    • Effective power consumption** kW – 1.97
    • Refrigerant – R 134a
    • Power Supply – 400 V, 3PH, 50Hz
    • Air connection (inner thread) – DN 40
    • Condensate Outlet – R 1/2
    • Dimensions H x W x D mm – 1277 x 1036 x 1128
    • Weight kg – 211

    THP 283-45

    • Flow rate at max. operational pressure** m3/min – 28.32
    • Differential pressure** bar – 0.81
    • Effective power consumption** kW – 2.93
    • Refrigerant – R 134a
    • Power Supply – 400 V, 3PH, 50Hz
    • Air connection (inner thread) – DN 50
    • Condensate Outlet – R 1/2
    • Dimensions H x W x D mm – 1277 x 1036 x 1144
    • Weight kg – 218

    THP 354-45

    • Flow rate at max. operational pressure** m3/min – 35.40
    • Differential pressure** bar – 0.74
    • Effective power consumption** kW – 4.48
    • Refrigerant – R 404a
    • Power Supply – 400 V, 3PH, 50Hz
    • Air connection (inner thread) – DN 50
    • Condensate Outlet – R 1/2
    • Dimensions H x W x D mm – 1277 x 1036 x 1144
    • Weight kg – 268

    THP 496-45

    • Flow rate at max. operational pressure** m3/min – 49.55
    • Differential pressure** bar – 0.65
    • Effective power consumption** kW – 5.19
    • Refrigerant – R 404a
    • Power Supply – 400 V, 3PH, 50Hz
    • Air connection (inner thread) – DN 80
    • Condensate Outlet – R 1/2
    • Dimensions H x W x D mm – 1464 x 1362 x 1525
    • Weight kg – 465

    THP 565-45

    • Flow rate at max. operational pressure** m3/min – 56.63
    • Differential pressure** bar – 0.81
    • Effective power consumption** kW – 8.02
    • Refrigerant – R 404a
    • Power Supply – 400 V, 3PH, 50Hz
    • Air connection (inner thread) – DN 80
    • Condensate Outlet – R 1/2
    • Dimensions H x W x D mm – 1464 x 1362 x 1525
    • Weight kg – 590

    THP 850-45

    • Flow rate at max. operational pressure** m3/min – 84.95
    • Differential pressure** bar – 0.81
    • Effective power consumption** kW – 10.21
    • Refrigerant – R 404a
    • Power Supply – 400 V, 3PH, 50Hz
    • Air connection (inner thread) – DN 80
    • Condensate Outlet – R 1/2
    • Dimensions H x W x D mm – 1464 x 1362 x 1525
    • Weight kg – 710

    THP 1061-45

    • Flow rate at max. operational pressure** m3/min – 106.18
    • Differential pressure** bar – 0.74
    • Effective power consumption** kW – 13.36
    • Refrigerant – R 404a
    • Power Supply – 400 V, 3PH, 50Hz
    • Air connection (inner thread) – DN 80
    • Condensate Outlet – R 1/2
    • Dimensions H x W x D mm – 1464 x 1362 x 1525
    • Weight kg – 719

    … up to 50 bar***
    THP 8-50

    • Flow rate at max. operational pressure** m3/min – 0.80
    • Differential pressure** bar – 0.25
    • Effective power consumption** kW – 0.23
    • Refrigerant – R 134a
    • Power Supply – 230 V, 1PH, 50Hz
    • Air connection (inner thread) – R1/2
    • Condensate Outlet – R 3/8
    • Dimensions H x W x D mm – 660 x 501 x 521
    • Weight kg – 39

    THP 13-50

    • Flow rate at max. operational pressure** m3/min – 1.30
    • Differential pressure** bar – 0.20
    • Effective power consumption** kW – 0.27
    • Refrigerant – R 134a
    • Power Supply – 230 V, 1PH, 50Hz
    • Air connection (inner thread) – R1/2
    • Condensate Outlet – R 3/8
    • Dimensions H x W x D mm – 660 x 501 x 521
    • Weight kg – 41

    THP 18-50

    • Flow rate at max. operational pressure** m3/min – 1.80
    • Differential pressure** bar – 0.22
    • Effective power consumption** kW – 0.42
    • Refrigerant – R 134a
    • Power Supply – 230 V, 1PH, 50Hz
    • Air connection (inner thread) – R1/2
    • Condensate Outlet – R 3/8
    • Dimensions H x W x D mm – 660 x 501 x 521
    • Weight kg – 43

    THP 27-50

    • Flow rate at max. operational pressure** m3/min – 2.70
    • Differential pressure** bar – 0.27
    • Effective power consumption** kW – 0.59
    • Refrigerant – R 134a
    • Power Supply – 230 V, 1PH, 50Hz
    • Air connection (inner thread) – R1/2
    • Condensate Outlet – R 3/8
    • Dimensions H x W x D mm – 660 x 501 x 521
    • Weight kg – 48

    THP 40-50

    • Flow rate at max. operational pressure** m3/min – 4.00
    • Differential pressure** bar – 0.25
    • Effective power consumption** kW – 0.68
    • Refrigerant – R 134a
    • Power Supply – 230 V, 1PH, 50Hz
    • Air connection (inner thread) – R1/2
    • Condensate Outlet – R 1/4
    • Dimensions H x W x D mm – 995 x 651 x 500
    • Weight kg – 114

    THP 50-50

    • Flow rate at max. operational pressure** m3/min – 5.00
    • Differential pressure** bar – 0.28
    • Effective power consumption** kW – 0.95
    • Refrigerant – R 134a
    • Power Supply – 230 V, 1PH, 50Hz
    • Air connection (inner thread) – R1/2
    • Condensate Outlet – R 1/4
    • Dimensions H x W x D mm – 995 x 651 x 500
    • Weight kg – 127

    *) Max. air inlet-/ambient temperature 50/43 °C – **) Performance data for reference conditions as per DIN/ISO 7183, Option A1: Max. operating pressure, ambient temperature +25 °C,
    compressed air inlet temperature +35 °C, pressure dew point +3 °C. Flow rates and differential pressure differ for other operating conditions. – ***) The max. operating pressure is reduced
    to 40 bar for inlet temperatures of +50 °C and higher